What is a qualified patchcord?
Many manufacturers over-emphasize the performance of back reflection and insertion loss figures but ignore the importance of topography measurement of the polished ferrule. The three main important measurements that characterize the shape of the polished connector endface are radius of curvature, vertex offset and undercut.

Radius of Curvature
This is defined as the radius of curvature of the portion of the endface that is domed by polishing for physical contact.

 

 


Vertex offset
Vertex offset indicates how well the sphere forming the connector endface is centered on the fiber. It is measured by determining the position of the highest point of the endface and measuring the distance between this point and the centre of the fiber

 


Undercut
Undercut is the difference in height between the surface of the ferrule and the surface of the fiber. Undercut is usually measured by finding two points which lie on the centerline of the fiber. One point lies where the sphere forming the surface of the ferrule intersects the centerline of the fiber. The second point lies where the surface of the fiber intersects the centerline of the ferrule. The distance between these two points is the undercut. Serious undercut can be seen at above picture.

ZJOPTIC Standard of topography measurement of polished ferrule
Measurement Parameter Pass/ Fail Limits (Min) Pass/Fail Limits (Max)
Radius of Curvature 10.0 mm 25.0 mm
Fiber Height (Spherical Fit) -50.0 nm 50.0nm
Fiber Height (Planar Fit) -10.0 um 150.0 nm
Apex Offset -0.00 um 50.0 um
Angle -0.3 degree 0.3 degree
Fiber Roughness (Rq) 0 nm 50 nm
Ferrule Roughness (Rq) 0 nm 50 nm
Diameter 125.0 um 135.0 um


Guaranteed Performance by ZJOPTIC
 

APC

UPC

PC

Insertion Loss (dB)

<0.2

<0.2

<0.2

Return Loss (dB)

>60

>50

>45

Testing System
In order to assure a satisfactory performance, a rigid testing procedure is applied to every patchcord assembled by ZJOPTIC. The aim of this testing procedure is to make sure every ZJOPTIC patchcords are in best condition before delivery.

Insertion Loss Test - For singlemode fiber optic cable
When tested in accordance with the GR-326-CORE, the maximum insertion loss shall not exceed 0.2dB against master connector. We apply company standard is max 0.2dB. ZJOPTIC typical value is 0.1dB.

For multimode fiber optic cable:
In accordance with FOTP-34 (interconnection device insertion loss test) and FOTP-171 (attenuation by substitution measurement), all tests are performed by advanced testing equipment. The maximum insertion loss shall not exceed 0.2dB against master connector. Again, typical value is 0.09dB.

Return Loss Test-For singlemode fiber optic cable only:
Strictly following FOTP-107, JDS-Uniphase RX and RM series Power and Back Reflection Meter is used as testing instrument.

Ferrule Surface Inspection
Every connector is inspected by 400X microscope to ensure there is no visible scratch on the fiber.


Topography measurement of the ferrule
DORC interferometer can display an accurate measurement of radius of curvature, fiber height, apex offset, fiber roughness and ferrule roughness. Sample checked by our QC manager could make sure all the critical parameters are within specifications defined by international organizations.